Air Receiver Installation Specification

  • Design Temperature
  • 80C
  • Air Pressure
  • 10 Bar
  • Volume of Tank
  • 2000 Liters
  • Design Pressure
  • 12 kg/cm
  • Air Inlet
  • 2 inch BSP
  • Inner Diameter
  • 800 mm
  • Working Presssure
  • 10 kg/cm
  • Color
  • Blue
  • Air Outlet
  • 2 inch BSP
  • Capacity
  • 2000 Liters
  • Height
  • 2500 mm
  • Tank Material
  • Mild Steel
  • Working Temperature
  • up to 50C
  • Dimension (L*W*H)
  • 800 mm x 800 mm x 2600 mm
  • Inspection Hole
  • Provided with inspection opening
  • Paint Finish
  • Epoxy Powder Coated
  • Shell Thickness
  • 8 mm
  • Connection Flange
  • Available on request
  • Operating Medium
  • Compressed Air
  • Mounting Type
  • Vertical, floor mounted
  • Corrosion Resistance
  • Yes, epoxy coated inner surface
  • End Cap Type
  • Hemisphere/Dished Ends
  • Manufacturing Standard
  • IS 2825/ASME Sec VIII Div 1
  • Safety Valve Provision
  • Yes
  • Drain Valve
  • 1 inch BSP
 
 

About Air Receiver Installation



Order Today and secure a Grand, Laureate-quality Air Receiver Installation, designed for a Towering performance with limited stock available for a limited time only. This robust, floor-mounted vertical unit boasts a hemispherical/dished end cap for superior strength and an 8 mm thick shell, all epoxy powder-coated for corrosion resistance. Enjoy easy inspection, reliable 1 inch BSP drain valve, safety provisions, and customization options. Built to IS 2825/ASME standards, it holds up to 2000 liters, operating safely at 10 Bar and 50C. Perfect for compressed air applicationsExporter, manufacturer, supplier in India.

Comprehensive Air Receiver Installation: Flexible Usage

Ideal for vertical floor mounting, this air receiver supports diverse industrial and commercial usage types. Its design ensures straightforward direction of useinstallation is simple, requiring only secure placement and connections for compressed air systems. Application places span manufacturing facilities, workshops, and service centers where reliable air storage is essential. The inspection port simplifies maintenance, making it a preferred choice for locations prioritizing operational safety and longevity.


Reliable Transportation and Supply: Ready Stock at FOB Port

Goods transport from our FOB port ensures secure movement and prompt delivery of your towering air receiver system. Stock is ready for dispatch, with robust packaging details to protect your investment during transportation. Our supply ability meets varying demand, whether for a single unit or bulk orders. Each unit is handled with care, ensuring the grand quality arrives intact and on timeperfect for businesses seeking efficiency and reliability in their operations.


FAQs of Air Receiver Installation:


Q: How is the air receiver installed and what mounting help is provided?

A: The air receiver is designed for vertical, floor mounting, with an inspection opening and connection flanges available on request. Installation guidance and service support are offered to ensure proper integration into your compressed air system.

Q: What benefits does the epoxy-coated inner surface offer?

A: The epoxy-coated inner surface delivers exceptional corrosion resistance, prolonging tank life and ensuring continued safe operation in demanding environments.

Q: When should inspection and maintenance be performed on the receiver?

A: Routine inspection is recommended at regular intervals, leveraging the inspection hole for visual and physical checks of internal surfaces, especially in facilities with frequent air usage.

Q: Where can this air receiver be used?

A: This air receiver is suitable for manufacturing plants, service centers, workshops, and any location needing robust compressed air storage with safety and corrosion protection.

Q: What is the maximum pressure and temperature the tank can safely handle?

A: The air receiver is engineered to safely operate at 10 kg/cm (10 Bar) and working temperatures up to 50C, with a design temperature of 80C, meeting stringent IS 2825/ASME standards.

Q: How are goods transported and delivered to buyers?

A: Goods are securely transported from the designated FOB port, with protective packaging and logistics coordination to ensure safe arrival and easy distribution to the buyers location.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Air Receiver Category

Air Receivers for air blaster

Air Receivers for air blaster

Tank Material : Other , Mild Steel (Seamless or Welded)

Color : Blue (Industrial Epoxy Paint)

Capacity : 400 Liters

Air Pressure : 8 to 12 kg/cm

Dimension (L*W*H) : 600 mm x 600 mm x 1500 mm

Working Temperature : Up to 65C

Safe Operation Electric Air Storage Receiver

Safe Operation Electric Air Storage Receiver

Tank Material : Other , Mild Steel

Color : Blue

Capacity : 1000 liters

Air Pressure : 10 Bar

Dimension (L*W*H) : 1000 x 1000 x 2200 mm

Working Temperature : 40C

Industrial Air Receiver Tanks

Industrial Air Receiver Tanks

Tank Material : Other , Mild Steel (MS), Stainless Steel (SS304/SS316) optional

Color : Blue (standard industrial paint finish, other options available)

Capacity : 500L, 1000L, 2000L, 3000L, 5000L, custom sizes

Air Pressure : 810 Bar

Dimension (L*W*H) : Depends on capacity (e.g., 1000 x 1000 x 2500 mm)

Working Temperature : 10C to 80C

Round Electric Mild Steel Vertical Air Receiver

Round Electric Mild Steel Vertical Air Receiver

Tank Material : Other , Mild Steel

Color : Blue

Capacity : 500 Liters

Air Pressure : 8 kg/cm

Dimension (L*W*H) : 600 x 600 x 2000 mm

Working Temperature : 50C




GST : 06AADCD1215A1ZL
Unit 1- 399, Sector-23, Faridabad - 121001, Haryana, India
Phone :07313726281
Mr. Gopakumar (Technical Head)
Mobile :07313726281


Unit 2- 368, Sector-24, Faridabad, Haryana - 121001